SPY700-FastAct™

$0.00
SKU
CY-SC605

SPY700-FastAct™ is a bright, far red, fluorogenic & non toxic F-actin stain based on our SPY™ dyes series. Its optimized structure allows to label F-actin in live cells with high specificity and low background. The unique and unmatched feature of SPY700-FastAct™ is its ability to label very fast actin dynamics. The probe does not require any genetic manipulation, transfection or overexpression of fluorescent proteins. SPY700-FastAct™ is based on our bright, photostable & far red SPY700 fluorophore which is far superior than fluorescent proteins. SPY700-FastAct™
enables multicolor imaging with SPY505, SPY555, SPY595, SPY650, SiR, GFP or m-cherry. SPY700-FastAct™ can be imaged with standard Cy5 filterset Cy5 filtersets but using a 700nm LP emission filter is best. It can be used for widefield, confocal, SIM or STED imaging in living cells and tissue. Contains 1 vial of SPY700-FastAct™ (lyophilized).

Absorbance maximum λabs

696 nm

Fluorescence maximum λfl

718 nm

Works on fixed cells?

No

Probe quantity

100 stainings*

Fluorescence lifetime

2.2 ns

STED depletion wavelength

>800 nm

Shipping

room temperature

Storage

-20°C


SPY700-FastAct in HUVECS

SPY700-FastAct™ in HUVECS with SPY505-DNA and SPY595-DNA

Emisson Spectra of SPY700-FastAct

Emisson Spectra of SPY700-FastAct

Check out this video of SPY700-FastAct™ in action

SPY700-FastAct, SPY505-DNA, SPY595-DNA, in HUVECS

If you have any questions concerning this product, please contact our Technical Service department at tservice@cytoskeleton.com

Q1. What is STED microscopy and how does it work?

A1. STED microscopy stands for Stimulated Emission Depletion microscopy.  It is one type of super resolution microscopy which allows the capture of images with a higher resolution than conventional light microscopy which is constrained by diffraction of light.  STED uses 2 laser pulses, one is the excitation pulse which excites the fluorophore, causing it to fluoresce.  The second pulse, referred to as the STED pulse, de-excites the fluorophore via stimulated emission in an area surrounding a central focal spot that is not de-excited and thus continues to fluoresce.  This is accomplished by focusing the STED pulse into a ring shape, a so-called donut, where the center focal spot is devoid of the STED laser pulse, conferring high resolution to the fluorescent area (Fig. 1; see Ref. 1 for more details on STED microscopy).

fig1-faq

Figure 1. STED microscopic image of microtubules labeled with SiR-tubulin in human primary dermal fibroblasts.

Q2. Why is the SPY actin (or tubulin/DNA) probe good for STED microscopy?

A2. STED microscopy offers the ability to study cellular details on a nanometermolar scale in vivo.  To take advantage of this super resolution microscopy, one must be able to select with high specificity the area to be examined using fluorescent probes.  In addition, the fluorescent probes must be bright, photostable, exhibit no or little phototoxicity, be excited and emit in the far red spectrum.  In addition, if the probe is to be used for live cell imaging (thus avoiding fixation artifacts that occur when cells are fixed), high cell permeability is necessary.  The SPY actin and tubulin probes fulfill all of these requirements.  In short, the combination of STED and SiR probes allows for unparalleled fluorescent visualization of subcellular actin and tubulin/microtubule structures and their physical characterization in living cells, (see Fig. 2 and Ref. 2). 

Neuron_actin_1
Neuron_actin_closup2_1

Figure 2. STED images of cultured rat hippocampal neurons stained with SiR-actin. Bottom image is a close-up view of part of the top image to clearly visualize actin rings (stripes) with 180 nm periodicity. Courtesy Of Elisa D'Este, MPI Biophysical Chemistry, Göttingen.

Q3: Are the SPY™ probes stable at room temperature?

A3: Yes, the probes are stable at room temperature for a few days.  However, it strongly depends on the probe and the solvent.  Thus, it is recommended to store all of the probes or solutions at –20°C.

 

Q4: Are SPY-actin, SPY-DNA and SPY-tubulin toxic to cells?

A4: Yes, above a certain threshold both probes show some effect on cell proliferation and altered actin or microtubule dynamics.  However, the probes are orders of magnitude less toxic than their parent drug.  In HeLa cells, neither actin nor microtubule dynamics were altered at concentrations below 100 nM.  At this concentration, SPY probes efficiently label microtubules and F-actin, allowing for the capture of high signal to noise images.


References

1. Hell S.W. and Wichmann J. 1994. Breaking the diffraction resolution limit by stimulated emission: stimulated-emission-depletion fluorescence microscopy. Opt. Lett. 19, 780-782.

2. D’Este E. et al. 2015. STED nanoscopy reveals the ubiquity of subcortical cytoskeleton periodicity in living neurons. Cell Rep. 10, 1246-1251.

3. Lukinavicius G. et al. 2013. A near-infrared fluorophore for live-cell super-resolution microscopy of cellular proteins. Nat. Chem. 5, 132-139.

4. Lukinavicius G. et al. 2014. Fluorogenic probes for live-cell imaging of the cytoskeleton.Nature Methods. 11, 731-733.