SPY650-tubulin

$0.00
SKU
CY-SC503

SPY650-tubulin is a bright, far-red & non toxic live cell  microtubule stain based on our SPYTM dyes series. Its optimized structure allows quick labeling of microtubules in live cells with high specificity and very low background. SPY650-tubulin stains microtubules in live cells without the need for genetic manipulation or overexpression of fluorescent proteins. Its absorbance and emission spectra are similar to Cy5. SPY650-tubulin enables multicolor imaging with SPY505, SPY555, SPY595, SPY700, GFP or m-cherry. SPY650-tubulin can be imaged with standard Cy5 filtersets. It can be used for widefield, confocal, SIM or STED imaging in living cells and tissue. Contains 1 vial of SPY650-tubulin (lyophilized).

Absorbance maximum λabs

652 nm

Fluorescence maximum λfl

674 nm

Works on fixed cells?

no

Probe quantity

100 stainings*

Fluorescence lifetime

3.0 ns

STED depletion wavelength

775 nm

Shipping

room temperature

Storage

-20°C

650

93X STED-imaged Dividing HeLa cell labeled with SPY555-actin (magenta), SPY595-DNA (orange), and SPY650-tubulin (blue). Image provided courtesy of Spirochrome.

For product Datasheets and MSDSs please click on the PDF links below.

Spirochrome Technical Tips and Ex/Em spectra in graphical form (PDF)

AuthorTitleJournalYearArticle Link
Machado, Marta et al.Plasmodium falciparum CRK4 links early mitotic events to the onset of S-phase during schizogonymBio2023ISSN 2150-7511
Houthaeve, Gaëlle et al.Transient nuclear lamin A/C accretion aids in recovery from vapor nanobubble-induced permeabilisation of the plasma membraneCellular and Molecular Life Sciences2022ISSN 1420-9071

Q1. What is STED microscopy and how does it work?

A1. STED microscopy stands for Stimulated Emission Depletion microscopy.  It is one type of super resolution microscopy which allows the capture of images with a higher resolution than conventional light microscopy which is constrained by diffraction of light.  STED uses 2 laser pulses, one is the excitation pulse which excites the fluorophore, causing it to fluoresce.  The second pulse, referred to as the STED pulse, de-excites the fluorophore via stimulated emission in an area surrounding a central focal spot that is not de-excited and thus continues to fluoresce.  This is accomplished by focusing the STED pulse into a ring shape, a so-called donut, where the center focal spot is devoid of the STED laser pulse, conferring high resolution to the fluorescent area (Fig. 1; see Ref. 1 for more details on STED microscopy).

fig1-faq

Figure 1. STED microscopic image of microtubules labeled with SiR-tubulin in human primary dermal fibroblasts.

Q2. Why is the SPY actin (or tubulin/DNA) probe good for STED microscopy?

A2. STED microscopy offers the ability to study cellular details on a nanometermolar scale in vivo.  To take advantage of this super resolution microscopy, one must be able to select with high specificity the area to be examined using fluorescent probes.  In addition, the fluorescent probes must be bright, photostable, exhibit no or little phototoxicity, be excited and emit in the far red spectrum.  In addition, if the probe is to be used for live cell imaging (thus avoiding fixation artifacts that occur when cells are fixed), high cell permeability is necessary.  The SPY actin and tubulin probes fulfill all of these requirements.  In short, the combination of STED and SiR probes allows for unparalleled fluorescent visualization of subcellular actin and tubulin/microtubule structures and their physical characterization in living cells, (see Fig. 2 and Ref. 2). 

Neuron_actin_1
Neuron_actin_closup2_1

Figure 2. STED images of cultured rat hippocampal neurons stained with SiR-actin. Bottom image is a close-up view of part of the top image to clearly visualize actin rings (stripes) with 180 nm periodicity. Courtesy Of Elisa D'Este, MPI Biophysical Chemistry, Göttingen.

Q3: Are the SPY probes stable at room temperature?

A3: Yes, the probes are stable at room temperature for a few days.  However, it strongly depends on the probe and the solvent.  Thus, it is recommended to store all of the probes or solutions at –20°C.

 

Q4: Are SPY-actin, SPY-DNA and SPY-tubulin toxic to cells?

A4: Yes, above a certain threshold both probes show some effect on cell proliferation and altered actin or microtubule dynamics.  However, the probes are orders of magnitude less toxic than their parent drug.  In HeLa cells, neither actin nor microtubule dynamics were altered at concentrations below 100 nM.  At this concentration, SPY probes efficiently label microtubules and F-actin, allowing for the capture of high signal to noise images.


References

1. Hell S.W. and Wichmann J. 1994. Breaking the diffraction resolution limit by stimulated emission: stimulated-emission-depletion fluorescence microscopy. Opt. Lett. 19, 780-782.

2. D’Este E. et al. 2015. STED nanoscopy reveals the ubiquity of subcortical cytoskeleton periodicity in living neurons. Cell Rep. 10, 1246-1251.

3. Lukinavicius G. et al. 2013. A near-infrared fluorophore for live-cell super-resolution microscopy of cellular proteins. Nat. Chem. 5, 132-139.

4. Lukinavicius G. et al. 2014. Fluorogenic probes for live-cell imaging of the cytoskeleton.Nature Methods. 11, 731-733.